IMAGING FOR RESIDENTS ANSWER
Year : 2021  |  Volume : 29  |  Issue : 3  |  Page : 223-225

A needle in a haystack


1 Department of Physical Medicine and Rehabilitation, University of Montreal Health Center, Montreal, Canada
2 Department of Physical Medicine and Rehabilitation, College of Medicine, Yeungnam University, Namku, Taegu, Republic of Korea

Date of Submission16-Apr-2020
Date of Decision28-Apr-2020
Date of Acceptance07-May-2020
Date of Web Publication27-Jun-2020

Correspondence Address:
Mathieu Boudier-Revéret
Hôtel-Dieu Du Centre Hospitalier De L'université De Montréal, 3840, Saint-Urbain St., Montreal, QC, H2W 1T8
Canada
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/JMU.JMU_60_20

Get Permissions


How to cite this article:
Mares C, Chang MC, Boudier-Revéret M. A needle in a haystack. J Med Ultrasound 2021;29:223-5

How to cite this URL:
Mares C, Chang MC, Boudier-Revéret M. A needle in a haystack. J Med Ultrasound [serial online] 2021 [cited 2021 Oct 26];29:223-5. Available from: http://www.jmuonline.org/text.asp?2021/29/3/223/288211




  Section 2 – Answer Top


Case

A 58-year-old, right-handed, female known for rheumatoid arthritis was seen in the outpatient clinic of our university hospital PM and R department for the left lateral elbow pain evolving over the last year.

She described mechanical pain over her left lateral epicondyle. On observation, there was no swelling, deformities, or scars. Physical examination revealed a positive Mills and Cozen sign. There was no ROM limitation. She had pain on palpation over her left lateral epicondyle.

A diagnostic ultrasound using a high-resolution linear multifrequency (7–18 Hz) probe on a Toshiba Aplio 500 ultrasound machine and a standardized elbow scanning protocol[1] revealed signs of tendinosis of the common extensor tendon without radial collateral ligament tears and absence of elbow effusion. While scanning the brachialis muscle in transverse axis at the distal arm level, the image was obtained [Figure 1]. Can you find the needle in the haystack?
Figure 1: On this transverse view of the ventral arm, approximately 3 cm proximal to the elbow joint, please localize and describe the anomaly

Click here to view



  Interpretation Top


On this short-axis view of the distal arm, we can see (centrally in the image) a hyperechoic zone within the brachialis muscle and a posterior reverberation artifact deep to it [Figure 2].
Figure 2: On this short axis, transverse view of the arm, approximately 3 cm proximal to the elbow joint, we demonstrate a central hyperechoic zone within the muscle fibers of the brachialis muscle lying anterior to the humerus (white arrow). There is a posterior reverberation deep to the area of interest

Click here to view


An elbow X-ray in 2017 revealed no significant findings, but a follow-up X-Ray soon after her appointment revealed the image [Figure 3]a and [Figure 3]b.
Figure 3: On this X-ray of the left elbow, we clearly demonstrate a 2.5 cm long by 1 mm wide needle superior and medial to the elbow joint, on the anteroposterior (a) and lateral (b) views

Click here to view


A 2.5 cm long by 1 mm wide needle was described proximal to the elbow joint and was not seen on previous X-ray 2 years prior. The patient could not recall any event related to this finding. She frequently goes for blood work related to her rheumatoid arthritis (blood usually drawn around the antecubital fossa), but could not recall any incident related to the broken needle. There was no history of intravenous drug use. We saw the patient in follow-up for further ultrasonographic evaluation to better evaluate the localization of the broken needle [Figure 4]a and [Figure 4]b and [Video 1].
Figure 4: A longitudinal view (a) and transverse view (b) of the aforementioned hyperechoic zone demonstrates the needle (white arrow) embedded within the brachialis muscle, approximately 1.5 cm deep, with a posterior reverberation and acoustic shadow artifact which helps us distinguish it from muscular fascia

Click here to view



Initial scanning of such a finding can prove to be tricky as septations and intramuscular fascia can give similar images to that of the needle. However, due to the posterior reverberation artifact, the needle was distinguished from intramuscular fascia both on short-axis and long-axis views.[2] The needle was situated in the brachialis muscle, approximately 2 cm proximal to the trochlea and 1.5 cm deep. There was no significant scar tissue around the needle, and it was not adjacent to any major neurovascular structure, specifically the radial and median nerves were not in proximity. No significant Doppler hyperemia was present.

Our hypothesis for the presented case is likely a broken needle during a routine blood test given the location of the needle. Contraction of the brachialis may have contributed to an initial proximal migration of the needle to its current resting position. Interestingly, thorough clinical and sonographic evaluation helped confirm that the needle is not symptomatic at this point in its current location. Her pain is exclusively localized to the lateral epicondyle and there is no pain on palpation (when sonographically guided) in the area of the needle nor with brachialis contraction or stretch. She had received one cortisone injection prior to seeing us for her lateral epicondyle pain, but the needle was not found near that site, so this hypothesis was discarded.

In the short term, we were reassured with the sonographical evaluation as it demonstrated the needle to be far from any important neurovascular structures and there was no pain or signs of infection clinically. Furthermore, this case was seen during the COVID-19 pandemic and it was deemed appropriate to limit health-care exposure at this time for a future consultation with our surgical colleagues.


  Discussion Top


Our literature review revealed this as a rare complication related to needle interventions. This complication seems to be most often reported in the dentistry literature related to local anesthesia and short and small gauge needles (mostly 30 gauge) which are more fragile to breakage.[3] The estimated risk of needle breakage in medical dentistry is reported to be 1 in 14 million inferior alveolar nerve blocks.[3] There is a theoretical risk of infection due to this foreign body or risk of migration and injury to nearby structures (especially neurovascular structures). Needle retrieval is also described in the medical dentistry and maxillofacial surgery literature.[4] Previously, magnets were once used for retrieval, but this is no longer used and surgical retrieval, when clinically indicated, is the procedure of choice.[5] We were unable to retrieve any reports of such cases in the interventional musculoskeletal literature.

Malamed et al. presented a review of this topic specific to medical dentistry with interesting recommendations at the end of their paper which can likely be generalized to any needle intervention.[3] Short and smaller gauge needles seem to be more prone to breakage. Needle bending and insertion of needle all the way to the hub should be avoided, especially if already using short and small gauge needles.[3],[6] Studies have shown that needle size does not correlate with pain perception; in fact, a thinner needle increases injection pressure and may cause increased pain.[7] Children or people with fear and apprehension of the procedure or of needles require more cautious injection, as a sudden, jerk-like reaction could increase the risk of needle breakage.[8]

Diagnostic ultrasonography is a key tool in musculoskeletal medicine. It has many advantages; however, it is important to remember that as a basic diagnostic workup, a complementary standard radiograph of the desired region should be requested to completely assess the desired region. This case highlights how it could have been easy to initially miss this incidental finding without the standard radiograph. There are well-described artifacts in ultrasonography (posterior reverberation and acoustic shadow) described here, which must can help the clinician further characterize these conditions. The role of ultrasonography and of the clinician is to be particularly attentive to all images and artifacts (such as reverberation) and rotate the probe 90° for further evaluation when suspicious images are seen.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient has given her consent for her images and other clinical information to be reported in the journal. The patient understands that her name and initials will not be published and due efforts will be made to conceal identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Özçakar L, Kara M, Chang KV, Hung CY, Tekın L, Ulaşlı AM, et al. EURO-MUSCULUS/USPRM basic scanning protocols for elbow. Eur J Phys Rehabil Med 2015;51:485-9.  Back to cited text no. 1
    
2.
Ricci V, Soylu AR, Özçakar L. Artifacts and artistic facts: A visual simulation for ultrasound training. Am J Phys Med Rehabil 2019;98:521-5.  Back to cited text no. 2
    
3.
Malamed SF, Reed K, Poorsattar S. Needle breakage: Incidence and prevention. Dent Clin North Am 2010;54:745-56.  Back to cited text no. 3
    
4.
Lee TY, Zaid WS. Broken dental needle retrieval using a surgical navigation system: A case report and literature review. Oral Surg Oral Med Oral Pathol Oral Radiol 2015;119:e55-9.  Back to cited text no. 4
    
5.
Kennett S, Curran JB, Jenkins GR. Management of a broken hypodermic needle: Report of a case. Anesth Prog 1973;20:48-50.  Back to cited text no. 5
    
6.
Ethunandan M, Tran AL, Anand R, Bowden J, Seal MT, Brennan PA. Needle breakage following inferior alveolar nerve block: Implications and management. Br Dent J 2007;202:395-7.  Back to cited text no. 6
    
7.
Augello M, von Jackowski J, Grätz KW, Jacobsen C. Needle breakage during local anesthesia in the oral cavity – A retrospective of the last 50 years with guidelines for treatment and prevention. Clin Oral Investig 2011;15:3-8.  Back to cited text no. 7
    
8.
Pogrel MA. Broken local anesthetic needles: A case series of 16 patients, with recommendations. J Am Dent Assoc 2009;140:1517-22.  Back to cited text no. 8
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
Section 2 –...
Interpretation
Discussion
References
Article Figures

 Article Access Statistics
    Viewed242    
    Printed10    
    Emailed0    
    PDF Downloaded7    
    Comments [Add]    

Recommend this journal